|| India's First Integrated Platform for Green Building Solutions ||

PM2510CVTH Pro Aurora Touch – NTU ( Air Quality Monitor )

Brand
4 out of 5
  • 3.5” Touch display
  • Relative error Maximum of ±10% and ±10μg/m3
  • Self calibrating. Can be manually calibrated by taking the device outdoors and long pressing Setup Button.
  • Measurement parameters: PM2.5, PM10, CO2, Temp, Humidity, TVOC
    <td colspan=”1″ rowspan=”2″ data-sheets-value=”{“1″:2,”2”:”< 0.3 μm

    Range Accuracy Resolution Response Time
    PM
    PM2.5: 0-999 μg/m3
    Less than 10 seconds when scene changes
    PM10: 0-1999 μg/m3
    CO2 0 to 5000ppm 50ppm +-3% 2 minutes
    Temperature 10 to 60 degrees C 1 deg C 0.1 deg C
    Humidity 0 to 90% RH 3% 1%
    TVOC 125-600ppb 15% 1ppb 15 minutes

Added to wishlistRemoved from wishlist 0
Add to compare
  Inquiry

Technical Specifications of air quality monitor

  • Portable
    • Size: 11.6cm*11.6cm*6cm
    • Power voltage: 5V
    • Can be charged via laptop/car USB
    • Weight: 370 gms
    • 2600mAh rechargeable battery
    • 3.5 hours of battery backup
  • Display
    • 3.5” Touch display
    • The desired parameter to be displayed as bold can be pressed to select. 
    • Limits for red, yellow, green colours can be configurable via the app. 

Warranty & Support

  • 1-year warranty against any manufacturing defects.
  • The client is responsible for getting the device to our facilities for all servicing. Service time 1 week.
  • Warranty is void if the device is opened, tampered with or electronics damaged due to mechanical shock.
  • Sensor change and calibration are not included in the warranty.

Working Principle

  • PM sensor uses laser scattering principle: Light scattering can be induced when particles go through the detecting area. The scattered light is transformed into electrical signals and these signals will be amplified and processed. The number and diameter of particles can be obtained by analysis because the signal waveform has certain relations with the diameter of the particles.
  • The CO2 sensor is NDIR based (Nondispersive infrared sensor).
  • TVOC is MOS Mems based sensor.
  • The temperature sensor is CMOS, Humidity is Capacitive.

Tested and calibrated against

  • PM: Beta Attenuation Monitor (BAM)
  • CO2: Can be self-calibrated to 400ppm outdoors by taking monitor outdoors and a long-pressing Setup button on the monitor.
  • Temp & Humidity calibrated with a master traceable to NABL.

Wi-Fi Connectivity

  • Connects to Wi-Fi. Data are available in Android and IOS apps along with Indian AQI, day, week, month history as well as outdoor data in different parts of the city.

User Reviews

0.0 out of 5
0
0
0
0
0
Write a review

There are no reviews yet.

Be the first to review “PM2510CVTH Pro Aurora Touch – NTU ( Air Quality Monitor )”

Your email address will not be published. Required fields are marked *

No more offers for this product!

General Inquiries

There are no inquiries yet.

PM2510CVTH Pro Aurora Touch – NTU ( Air Quality  Monitor  )
PM2510CVTH Pro Aurora Touch – NTU ( Air Quality Monitor )
Econaur
Logo
Compare items
  • Total (0)
Compare
0

FREE

Sustainable Material Guide

E-Book

Sustainable Material Guide
Shopping cart